Equipment of the Chair of Electrical Power Supply Networks

Inverter laboratory

Grid model for decentralized feed-in to the low-voltage grid

Three inverters (10 kVA) that can be controlled by DC power supply units (12 kVA)

Flexible, modular grid simulation of a typical or extreme rural grid spur including transformer consisting of resistors in inductors

Comprehensive measurement technology for recording all relevant grid parameters (5 x Siemens Sentron PAC 4200) as well as supporting measurements by Fluke grid analyzer if required

Automated control and data acquisition

  

PV system for research purposes

PV system on the roof of the institute building with 14.04 kWp

Comprehensive, second-by-second measurement of all relevant data

 

Simulationstools

DIgSILENT Power Factory
Program for network calculation

NETOMAC
Program for network calculation

PSS SINCAL
Program for network calculation

Matlab
MATLAB is a commercial, platform-independent software for solving mathematical problems and displaying the results graphically

 

Practical course in energy transmission technology

Experiment stands with the following equipment

Model for line simulation

transformer

Synchronous generator including control unit

Ohmic loads

Capacitive loads

Inductive loads

Circuit breaker

Various line protection relays including control software

Various measuring devices

 

 

Network analyzer

Netzanalysator Fluke 435-II

Measurement of current, voltage, frequency, harmonics, power and energy, asymmetry, flicker, transients, inverter efficiency, recording the signal shape of events, inrush current, voltage dips and increases as well as an integrated energy loss calculator; Compliance with IEC 61000-4-30, Edition 2, Class A;